Alarm host

Brearley - Top 10 Chinese Security Brands

Home / Product / Storage & Application / Explosion-proof alarm products / Alarm host / BL-EXA256 256-way bus system explosion-proof alarm host

BL-EXA256 256-way bus system explosion-proof alarm host

Application scenarios:
The equipment has obtained the highest certification of Class II explosion-proof level and the temperature ( T ) the highest level of certification, suitable for A , II B , II C surroundings, T1 ~ T6 Group of explosive mixtures of explosive and flammable gases and air 0 Area, 1 Area, 2 Areas and places where explosive and flammable dust is mixed with air 20 Area, 21 Area, 22 In addition to coal mine methane gas, other explosive gas and dust environments in the area with explosive risk. Such as: refining, oil production, gas production, chemical industry, fireworks production, food processing and storage, gas stations and other environments.

Features:
· Explosion-proof mark: Exd IIC T6 Gb /ExtD A21 IP68 T80 °C
· Protection class: IP68
· Product Standards: Q/006-2016
· Stainless steel material design, double explosion-proof certification

support 256 Road alarm input, 256 Road alarm output

support 3 network 6 Center: wired network, wireless GPRS , telephone line, each communication method can upload alarm information to two independent platforms , And can realize redundant backup reporting

Supports two buses, the bus is non-polar, and each bus can be extended to 7.2km

Support remote control, credit card, keyboard, SMS and other arm and disarm methods

Support software visual programming, import and export of configuration parameters, convenient maintenance

contact us
  • BL-EXA256 256-way bus system explosion-proof alarm host

Alarm input

Onboard 8 , which can be extended to 256 indivual

Alarm Output

Onboard 4 , which can be extended to 256 indivual

Tamper Alarm

Support local 8 1 basic zone detector tamper alarm

timed output

support

Timed arm and disarm

Support (daily planning, priority planning)

Short message( -G support)

Support SMS alarm, fire alarm, arm and disarm

subsystem

support 8 an independent subsystem, 1 common subsystem

network port

1 indivual RJ45 , 10M/100M adaptive

telephone line

1 road PSTN

GPRS ( -G support)

1 indivual UIM card slot, 1 indivual SMA Antenna interface, support GPRS

remote control

32 indivual , Requires the host to cooperate with the keyboard to achieve (maximum remote control distance 100 Meter)

Number of external keyboards

32 keyboard

battery

1 Group interface for battery access 12VDC 7Ah

Bus wire diameter

RVV2*1.5

alternating current

220V AC